Software Overview
- CyScan
- Run by double clicking the CyScan desktop icon. Used to drive the WBX scanner, and its the front-end for scan merging. Loads IV files. License is tied to the scanner PC.
- PlyEdit
- Called by CyScan's Merge routine, and it merges the four overlapping scan files into a single surface. Creates PLY files. License is tied to the scanner PC.
- AutoFill
- Called by PlyEdit's Body AutoFill routine, and its used to fill all the holes, with arm segments placed to stop the auto-fill from joining the arms to the torsu, and a crotch segment placed to stop the legs being joined at the top. License is tied to the scanner PC.
- CySize
- Run by dragging merged a PLY file onto the "headus CySlice" desktop icon. Its used to extract measurements from the filled scans. License is tied to the dongle, so can be run from any configured PC.
CySize Installation
- Open up your clients page.
- Download and run the latest (closest to top of list) icyslice-*.exe file to install CySlice.
- Download and run the HDD-Win-*.exe file to install the dongle driver.
- Double click the headus CySlice desktop icon to run the Licensing GUI. You should see 2d7a1ec1 next to the Dongle label when the dongle is attached.
- Click on the Edit button, and cut and paste the line of hex number under Current Keys on your clients page into the Notepad window.
- Save the keys file, then click on the Refresh button in the Licensing GUI. You should then see permanent next to CySlice.
CySize Measurement Codes
Magenta Curves
C = Point to point caliper measurement. S = Over surface length T = Convex hull tape measure length
White Sections
A = Cross-sectional area S = Over surface girth T = Convex hull tape measure girth
Red Volumes
V = Volume A = Surface area; doesn't include fill